Grooved indicator dial - 1175MZ - 1175MZ
STT65032
Prix régulier
$4,288.90
Preorder today
- The machine-divided rules ensure uniformity of line width and depth
- The bar itself is also adjustable for more or less reach.
- A fine adjustment screw and a lock are also supplied
- Supplied with two sets of jaws, both easily interchangeable.
- Three sets of contacts are provided (styles 1-10, 2-10, 2-20) which can be attached to the ends of the jaws without replacing the entire jaw
- The contacts have flush ends so that the grooves at the bottom of the blind holes can be gauged.
- The instrumentation can be adjusted using instrumentation blocks or other methods such as micrometers, vernier calipers, and ring gauges.
- The machine-divided rules ensure uniformity of line width and depth
- The bar itself is also adjustable for more or less reach.
- A fine adjustment screw and a lock are also supplied
- Supplied with two sets of jaws, both easily interchangeable.
- Three sets of contacts are provided (styles 1-10, 2-10, 2-20) which can be attached to the ends of the jaws without replacing the entire jaw
- The contacts have flush ends so that the grooves at the bottom of the blind holes can be gauged.
- The instrumentation can be adjusted using instrumentation blocks or other methods such as micrometers, vernier calipers, and ring gauges.
STT65032
Prix régulier
$4,288.90
Preorder today
- The machine-divided rules ensure uniformity of line width and depth
- The bar itself is also adjustable for more or less reach.
- A fine adjustment screw and a lock are also supplied
- Supplied with two sets of jaws, both easily interchangeable.
- Three sets of contacts are provided (styles 1-10, 2-10, 2-20) which can be attached to the ends of the jaws without replacing the entire jaw
- The contacts have flush ends so that the grooves at the bottom of the blind holes can be gauged.
- The instrumentation can be adjusted using instrumentation blocks or other methods such as micrometers, vernier calipers, and ring gauges.
- The machine-divided rules ensure uniformity of line width and depth
- The bar itself is also adjustable for more or less reach.
- A fine adjustment screw and a lock are also supplied
- Supplied with two sets of jaws, both easily interchangeable.
- Three sets of contacts are provided (styles 1-10, 2-10, 2-20) which can be attached to the ends of the jaws without replacing the entire jaw
- The contacts have flush ends so that the grooves at the bottom of the blind holes can be gauged.
- The instrumentation can be adjusted using instrumentation blocks or other methods such as micrometers, vernier calipers, and ring gauges.